CVE-2020-27361 (akkadian_provisioning_manager)
An issue exists within Akkadian Provisioning Manager 4.50.02 which allows attackers to view sensitive information within the /pme subdirectories. Devamını Oku
An issue exists within Akkadian Provisioning Manager 4.50.02 which allows attackers to view sensitive information within the /pme subdirectories. Devamını Oku
An issue exists within Akkadian Provisioning Manager 4.50.02 which allows attackers to view sensitive information within the /pme subdirectories. Devamını Oku
The debug-meta-data plugin 1.1.2 for WordPress allows XSS. Devamını Oku
An issue was discovered in IdeBusDxe in Insyde InsydeH2O 5.x. Code in system management mode calls a function outside of SMRAM in response to a crafted software SMI, aka Inclusion of Functionality from an Untrusted Control Sphere. Modifying the well-known address of this function allows an attacker to gain control of the system with the…
The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal…
A stack buffer overflow in Realtek RTL8710 (and other Ameba-based devices) can lead to remote code execution via the "memcpy" function, when an attacker in Wi-Fi range sends a crafted "Encrypted GTK" value as part of the WPA2 4-way-handshake. Devamını Oku
A stack buffer overflow in Realtek RTL8710 (and other Ameba-based devices) can lead to remote code execution via the "AES_UnWRAP" function, when an attacker in Wi-Fi range sends a crafted "Encrypted GTK" value as part of the WPA2 4-way-handshake. Devamını Oku
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files. Devamını Oku
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files. Devamını Oku
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface. Devamını Oku
An exploitable SQL injection vulnerability exists in ‘listImmoLabels.jsp’ page of OpenClinic GA 5.173.3 application. The immoComment parameter in the ‘listImmoLabels.jsp’ page is vulnerable to authenticated SQL injection. An attacker can make an authenticated HTTP request to trigger this vulnerability. Devamını Oku