CVE-2020-25218
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface. Devamını Oku
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface. Devamını Oku
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allows Command Injection as root in its administrative web interface. Devamını Oku
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allows Command Injection as root in its administrative web interface. Devamını Oku
The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 allows authenticated command injection in the Throughput, WANStats, PhyStats, and QosStats API classes. An attacker with access to a web console account may execute operating system commands on affected devices by sending crafted POST requests to the affected endpoints (/core/api/calls/Throughput.php, /core/api/calls/WANStats.php, /core/api/calls/PhyStats.php, /core/api/calls/QosStats.php).…
The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device's filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message…
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak: National Vulnerability Database
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.…
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. Zafiyet ile ilgili Genel Bilgi, Etki ve Çözümleri için Devamını Oku Kaynak:…
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated…
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files. Zafiyet ile ilgili Genel Bilgi, Etki…
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead…