CVE-2020-36511
An issue was discovered in the bite crate through 2020-12-31 for Rust. read::BiteReadExpandedExt::read_framed_max may read from uninitialized memory locations. Devamını Oku
An issue was discovered in the bite crate through 2020-12-31 for Rust. read::BiteReadExpandedExt::read_framed_max may read from uninitialized memory locations. Devamını Oku
An issue was discovered in the buffoon crate through 2020-12-31 for Rust. InputStream::read_exact may read from uninitialized memory locations. Devamını Oku
An issue was discovered in the acc_reader crate through 2020-12-27 for Rust. read_up_to may read from uninitialized memory locations. Devamını Oku
An issue was discovered in the acc_reader crate through 2020-12-27 for Rust. fill_buf may read from uninitialized memory locations. Devamını Oku
An issue was discovered in the smallvec crate before 0.6.13 for Rust. It can create an uninitialized value of any type, including a reference type. Devamını Oku
An issue was discovered in the actix-web crate before 0.7.15 for Rust. It can unsoundly coerce an immutable reference into a mutable reference, leading to memory corruption. Devamını Oku
The package parse-link-header before 2.0.0 are vulnerable to Regular Expression Denial of Service (ReDoS) via the checkHeader function. Devamını Oku
All versions of package js-data are vulnerable to Prototype Pollution via the deepFillIn and the set functions. This is an incomplete fix of [CVE-2020-28442](https://snyk.io/vuln/SNYK-JS-JSDATA-1023655). Devamını Oku
This affects all versions of package github.com/kataras/iris; all versions of package github.com/kataras/iris/v12. The unsafe handling of file names during upload using UploadFormFiles method may enable attackers to write to arbitrary locations outside the designated target folder. Devamını Oku
Unprotected transport of credentials vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from the…
Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from…
Incorrect permission assignment for critical resource vulnerability in GroupSession Free edition ver5.1.1 and earlier, GroupSession byCloud ver5.1.1 and earlier, and GroupSession ZION ver5.1.1 and earlier allows a remote unauthenticated attacker to access arbitrary files on the server and obtain sensitive information via unspecified vectors. Devamını Oku